+86-23-65764808

Products
Home / Product Category / Powered Surgical Instruments / Powered Surgical Instruments / Micromotor / Micromotor 150w
Micromotor 150w
Micromotor 150w Micromotor 150w
Micromotor 150w Micromotor 150w
Micromotor 150w Micromotor 150w

loading

Micromotor 150w

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Indication
  • Neurosurgery
  • Spine Surgery
  • Orthopedic Surgery
  • ENT Surgery
  • DJ4A / DJ20

Availability:


Product Overview

The 150W high-torque medical micromotor (Models: DJ4A / DJ20) is a heavy-duty surgical device developed by CXISHAN for complex orthopedic, spine and neurosurgery procedures. With a higher power output and torque compared to standard micromotors, this device excels in handling tough bone and tissue cutting tasks. It integrates high-efficiency brushless technology and an integrated smart cooling system to ensure stable performance under heavy loads, while its fully sealed design supports high-temperature steam sterilization, meeting the strict hygiene standards of clinical environments. As a core tool for complex surgeries, it combines power, precision and durability to assist surgeons in achieving optimal surgical outcomes.


DJ4A



Key Advantages

High-Power Brushless Technology for Heavy-Duty Tasks

The 150W medical micromotor adopts high-efficiency brushless technology to deliver a rated power of 150W and a torque of 29 mNm, making it ideal for complex surgical procedures that require strong cutting force. The brushless design reduces mechanical wear, extends service life and avoids debris contamination in the surgical field.

Smart Cooling System for Continuous Operation

Equipped with an automatic air-cooling system, the micromotor maintains optimal operating temperature even during prolonged heavy-load use. The integrated smart cooling system prevents overheating, ensuring consistent speed and torque output, which is critical for complex surgeries that demand uninterrupted device performance.

135°C Steam Sterilizable Sealed Structure

The fully sealed design of the 150W high-torque micromotor supports 135°C high-temperature steam sterilization, fully complying with hospital infection control protocols. The sealed structure effectively prevents the entry of surgical fluids and contaminants, ensuring the safety and hygiene of each surgical application.



Technical Specification

The 150W medical micromotor is optimized for high torque and continuous heavy-load operation, with technical parameters that meet the demands of complex surgical procedures. Below are the detailed parameters in text description and table form:

This micromotor offers a maximum speed of 40,000 rpm, paired with a 150W high power output and 29 mNm torque, providing strong cutting and drilling capabilities for tough bone tissues. Its automatic air-cooling system ensures stable performance during long surgeries, and the steam autoclavable feature makes it easy to sterilize and reuse, enhancing its clinical practicality.


Technical Parameters

Details

Max Speed

40,000 rpm

Rated Power

150W

Torque

29 mNm

Steam Autoclavable

YES

Cooling System

Automatic air-cooling



Attachments & Tools

The 150W high-torque medical micromotor is compatible with a comprehensive range of specialized attachments, enabling surgeons to adapt the device to different surgical scenarios. The available attachments include:

Slim Bur Handpiece

Micro Bur Handpiece

Spinal Bur Handpiece

High-speed Handpiece

Bendable Bur Handpiece

Small Bone Attachment

Micro Cannulated Drill

Micro Sagittal Saw

Micro Oscillating Saw

Micro Reciprocating Saw



FAQ

What is the core difference between the 150W micromotor and the 100W version?

The main difference lies in power and torque. The 150W medical micromotor delivers 150W power and 29 mNm torque, suitable for heavy-duty complex surgeries, while the 100W version is more focused on precise delicate procedures.

Can this micromotor be sterilized with standard hospital equipment?

Yes. The micromotor supports 135°C steam sterilization, which is compatible with most hospital autoclave equipment, meeting routine sterilization needs.

Is the 150W micromotor easy to operate for different surgical scenarios?

Absolutely. With a full range of compatible attachments, the micromotor can be quickly adjusted for neurosurgery, orthopedic surgery, spine surgery and ENT surgery, ensuring flexible operation in different clinical settings.


Previous: 
Next: 

Quick Links

Product Category

About Us

Technology

Copyrights  2024 Chongqing Xishan Science & Technology Co., Ltd. All Rights Reserved. Sitemap
Disclaimer: The content on this site may not be permitted in your country.Please check the local healthcare regulations and exit if necessary.Xishan is not liable for any consequences arising from your access to this information.Additionally,some products may not be available in your region.For accurate information,please refer to the approved uses,as this content is not intended for markets where it is not authorized.

  +86-23-65764808