+86-23-65764808

Products
Home / Product Category / Powered Surgical Instruments / Powered Surgical Instruments / Bur / Arthroscopy Bur
Arthroscopy Bur
Arthroscopy Bur Arthroscopy Bur
Arthroscopy Bur Arthroscopy Bur
Round Stainless-Steel Arthroscopy Bur Round Stainless-Steel Arthroscopy Bur
Arthroscopy Bur Arthroscopy Bur

loading

Arthroscopy Bur

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button
Indication:
  • Subacromial Decompression
  • Bone Spur Removal (Osteophyte Excision)
  • Malleolar or Tibial Plafond Reshaping
  • Acetabular Rim Trimming
  • Notchplasty
  • GZT

Availability:


Product Overview

The Arthroscopy Bur is a high-performance rotary surgical tool engineered for minimally invasive arthroscopic procedures. It is specifically designed to address key orthopedic needs including subacromial decompression, bone spur removal (osteophyte excision), malleolar or tibial plafond reshaping, acetabular rim trimming, and notchplasty. Made of premium stainless steel, this tool comes in both reusable and single-use types, catering to diverse surgical settings and infection control requirements. As a core component of arthroscopic surgical systems, it enables surgeons to perform precise tissue cutting and shaping with minimal trauma, making it an indispensable device for modern orthopedic surgeries.

Arthroscopy Bur



Key Advantages

Minimally Invasive Design

The Arthroscopy Bur supports small incision surgeries, significantly reducing tissue trauma during the operation. This advantage directly lowers postoperative pain levels for patients and shortens their recovery period.

High Precision and Adjustable Control

It features high-speed rotary cutting with adjustable settings, adapting to different target tissues such as meniscus, cartilage, and synovium. Surgeons can flexibly adjust the working mode according to the surgical site, ensuring accurate operation and avoiding damage to surrounding healthy tissues.

Optimized Surgical Visualization

The integrated suction function of the Arthroscopy Bur effectively removes surgical debris in real time. It maintains a clear surgical field throughout the procedure, helping surgeons improve operational efficiency and reduce the risk of surgical complications.



Technical Specification

The Arthroscopy Bur has standardized technical parameters to meet the needs of various arthroscopic surgeries. Its core specifications are shown in the following text and table:

This tool has a straight shape for easy operation in narrow joint spaces. The effective length is fixed at 130 mm, suitable for most joint surgery scenarios. The tube diameter offers three options: 4.0 mm, 4.5 mm, and 5.0 mm, allowing surgeons to select the appropriate size based on the surgical site and patient condition. The working speed ranges from 6,000 r/min to 12,000 r/min, providing sufficient cutting power for different tissue types.

Specification Item

Details

Product Type

Reusable / Single-use

Effective Length

130 mm

Tube Diameter

4.0 mm / 4.5 mm / 5.0 mm

Working Speed

6,000 ~ 12,000 r/min

Shape

Straight

Material

Stainless Steel

Applicable Procedures

Subacromial Decompression, Bone Spur Removal, etc.



Attachments & Tools

The Arthroscopy Bur must be used with matching accessories to exert its surgical function. The dedicated attachment is:

- Arthroscopy Shaver Handpiece PSB2: This handpiece serves as the operation control terminal of the bur. It connects the bur to the power system, enabling speed adjustment and suction control to ensure stable and efficient surgical operation.



FAQ

Arthroscopy BurCan the reusable be sterilized multiple times?

Yes, the reusable type is made of high-quality stainless steel. It can withstand high-temperature and high-pressure sterilization procedures multiple times without affecting its structural stability and cutting performance.

What is the difference between different tube diameter specifications of the bur?

Smaller diameter options (4.0 mm) are suitable for narrow joint spaces such as finger joints. Larger diameters (4.5 mm/5.0 mm) provide stronger cutting power and are more suitable for procedures like tibial plafond reshaping that involve thick bone tissue.

Arthroscopy BurDoes the require professional training for operation?

Yes, it is a professional surgical tool. Surgeons need to receive systematic training on arthroscopic equipment operation to master the speed adjustment and suction control skills, ensuring surgical safety.


Previous: 
Next: 

Quick Links

Product Category

About Us

Technology

Copyrights  2024 Chongqing Xishan Science & Technology Co., Ltd. All Rights Reserved. Sitemap
Disclaimer: The content on this site may not be permitted in your country.Please check the local healthcare regulations and exit if necessary.Xishan is not liable for any consequences arising from your access to this information.Additionally,some products may not be available in your region.For accurate information,please refer to the approved uses,as this content is not intended for markets where it is not authorized.

  +86-23-65764808